How Storage Heaters Work. How storage heaters work is very straight forward.

Electricity to the units is restricted to off peak hours. Download Air Gun Ballistic Program Free. When 'on', electricity heats the elements, which in turn heat the bricks. Although surrounded in a layer of insulation as the brick get hotter the casing of the heater becomes hotter.

Free Fursona Template. Operating instructions for creda storage heaters how do you work creda storage heater model No. Where can I get a manual for Creda Storage Heater model #79164C?

CREDA - 1/79161 Storage Heater Parts. Storage Heater Spare Parts Supplier For Orders Telephone: 70 and Fax: 01. This can save up to 15% of the energy used by ordinary storage heaters. Combination with the storage heater for a rapid. Creda take the pain out of your.

Essentially it is the heat from the casing that heats the room. In recent years additional heat is released from the heater by the operation of a damper valve or output control. The basis of how storage heaters work is simple although often misunderstood. Yes it takes energy at night time and first thing in the morning it's at it's hottest, but - it's overnight when outside temperatures are coldest. As the day progresses the bricks become cooler and hence the heat output decreases.

But this is exactly what is needed as the outside temperature is rising. In the evening the casing is becoming cool, there is no doubt most of the heat has been expended. However the storage heater has done its job pretty well in that the fabric of the room walls act like a large storage heater maintaining comfort. There is no doubt if the external temperature in the evening drops suddenly the storage heater may be found wanting and this is when the Output controls comes in to play as will be explained later. How Storage Heaters Manual Controls Work Storage heaters are very straight forward to adjust. Essentially every heater has 2 controls, an Input control and an Output control. The main control is the Input control.

Input control determines the level of heat stored over night and hence the heat of the casing. The setting of the Input control will have the greatest influence on the level of comfort and also on the running costs. Like the control on a cooker, the higher the setting the more heat stored and hence the more heat released. Maximum setting will certainly be needed in winter but it can be reduced in autumn and spring for more economical operation. The Output or 'boost control' plays a smaller but none the less important role. The original storage heater just released heat from the casing. Off peak periods were typically long 11 or even 15 hours per day.

However when Economy 7 was promoted in the 1980's manufacturers sought to release as much of the heat stored in the brick as possible. To this end the damper valve or Output control was developed. When the damper control or Output control is opened air directly enters the brick core and is released from the grille at the top of the heater. The Output control is now operated by a piece of bimetal so that only when the brick core is cooling down the damper valve will open to release the last of the stored heat.

The use of the bimetal allows the Output control to be set in one position and then operate automatically day after day. Set to minimum the Output control will not operate the damper valve.